| Type / Model | : | MC2 – XWHM – Y OE |
| Size | : | 4.4 x 2.4 x 1.1 in. / 11.3 x 6.0 x 2.9 cm |
| Weight | : | 6 oz. / 171 g |
| Temperature | : | -4 to +122°F / -20 to +50°C |
| Humidity | : | 0% - 95% RH (non-condensing) |
| Alarms | : | - Visual, vibrating, audible (95 dB)
- Low, High, STEL, TWA, OL (over limit) |
| Tets | : | Audible/visual alarms on activation, sensors, battery and circuitry (continuous) |
| Pump | : | Compatible with the Sampler motorized sampling pump |
| Typical Battery Life | : | 10 hours (typical); recharges in less than 4 hours |
| User Option | : | Confidence beep
Combustible gas measurement Set STEL interval Measurement (% LEL or % by volume methane) |
| Type / Model | : | GA24XT-H |
| Size | : | 1.1 x 2.0 x 3.2 in. / 2.8 x 5.0 x 8.1 cm |
| Weight | : | 2.7 oz. / 76 g |
| Typical Battery Life | : | Two years (H2S, CO, SO2 or O2) or three years (H2S or CO) |
| Certifications | : | h Class I, Div. 1, Gr. A, B, C, D American Bureau of Shipping |
| Approval | ||
| ATEX | : | X g II 1 G |
| Ex | : | ia IIC T4 |
| IECEx | : | Ex ia IIC T4 |
| INMETRO | : | BR-Ex ia IIC T4 |
| X | : | European Conformity |
| Warranty | : | 2 or 3 years from activation (given normal operation), plus 1 year shelf life |
| Type / Model | : | X-am 3000 |
| Size (h x w x d, approx) | : | 90 x 140 x 55 mm, 3.5‘‘ x 5.5‘‘ x 2.2‘‘ |
| Weight (approx) | : | 550 g, 20 oz |
| Ambient Conditions | ||
| Temperature | : | - 20 to + 55 °C; - 5 to + 130 °F short term - 40 to + 55 °C; - 40 to + 130 °F |
| Pressure | : | 700 to 1300 hPa, 20.7 to 38.4 inch Hg |
| Humidity | : | 10 to 95 %RH |
| Enclosure Rating | : | IP 65 |
| Typichal Battery Life | ||
| Alkaline | : | > 24 hours (diffusion mode) > 12 hours (pump mode) |
| NiMH | : | > 18 hours (diffusion mode) > 12 hours (pump mode) |
| Audible Alarm | : | > 90 dB (A) at a distance of 30 cm; 1 ft. |
| Charging Time | : | < 4 hours |
| Pump Mode | : | maximum length of tubing 20 m |
| Approval | ||
| ATEX | : | II 2G EEx ia d IIC T4; - 25 ≤ Ta ≤ + 55 °C (rechargeable) - 25 ≤ Ta ≤ + 50 °C (Alcaline) I M2 EEx ia d l |
| UL | : | Class I, Div 1, Group A, B, C, D; Temp Code T4 |
| CSA | : | Class I, Div 1, Group A, B, C, D; Temp Code T4 |
| IECEx | : | Ex ia d I/IIC T4; - 25 ≤ Ta ≤ + 55 °C (rechargeable) - 25 ≤ Ta ≤ + 50 °C (Alcaline) |
| CE-mark | : | electromagnetic compatibility (directive 89/336/EEC) |